RK-MCU (EN-D)

INTEVIO Master Control Unit and Push-to-talk Microphone

RK-MCU Master Control Unit is the central management device of the INTEVIO PA / VA system, which is used to manage and monitor all devices and perform various operations. RK-MCU provides audio storage, broadcast, zone control, monitoring, timing control and fault diagnosis functions. The built-in 500W digital power amplifier can drive upto 8 loudspeaker lines to meet requirements for smaller PA / VA applications. It can also be connected to zone expanders to increase system capacity for the requirements of large applications.

FUNCTIONS

The controller integrates multiple functions such as audio storage, playback, zone control, audio monitoring, scheduled broadcast and fault diagnosis.

Automatic fault diagnosis

The INTEVIO system is a fully monitored system with the ability to supervise and report faults related to the main power, backup power, CPU, microphone, amplifiers, loudspeaker circuits and dry contacts. Fault details are displayed on the LCD screen with fault logs stored in the internal memory.

Allow all calls even when the CPU malfunctions

If the CPU of the RK-MCU fails the INTEVIO system will still allow the user to make paging announcements (All Call) using the PT T Microphone in case of emergencies.

Scheduled broadcast with built-in timer

RK-MCU has a built-in timer and supports configurable scheduled broadcast.

Record and play

RK-MCU allows users to record temporary messages into its built-in 1GB memory with the PTT microphone or the call station and broadcast without configuration. This delivers improved operational efficiency, in applications such as small shopping malls/supermarkets where promotional messages are updated frequently.

Cost saving amplifier backup solution

RK-MCU has a built-in amplifier automatic switch-over function and allows different amplifier backup configurations to address the needs of different applications. To back up all the amplifiers in the system, a minimum of one standby amplifier is sufficient, which greatly reduces the ownership cost on standby amplifiers.

• Integrated public address and voice alarm system controller

• Maximum 8 loudspeaker zones with a maximum power rating of 500 W for each speaker line

• 10 supervised dry contact inputs and 8 dry contact outputs

• Built-in 500 W Class D power amplifier

• Increased operational efficiencies: plug and play, record and play, interaction between LCD and buttons

• Integration with third party systems, such as fire alarm systems through dry contacts

• Integrated recorder, timer, audio monitor and one-for-all backup amplifier solutions

• Supports for both single and dual channel

• Two auxiliary inputs and one MIC/LINE input

• Support for external power amplifiers

• Built-in standard configuration allows use directly following installation

• System functionality can also be programmed via configuration software

• Built-in 1 GB Flash memory and 4 GB SD card, for storage of audio files, recording files, configuration data and log files

• Management of all public address and emergency broadcast devices on the system, providing device status information and control via the LCD screen

• Flexible power amplifier redundancy

• One spare amplifier can back up all amplifiers in the system

ราคา:
0.00 THB
หมวดหมู่:
Intevio
ปรับปรุงล่าสุด:
29 มีนาคม 2024
RK-MCU (EN-D) INTEVIO Master Control Unit and Push-to-talk Microphone บริษัท โฮมเทล อินเตอร์เนชั่นแนล จำกัด
สอบถาม
สินค้าที่เกี่ยวข้อง
Cabinet Loudspeaker L-PWP06A

Packed with features like a high-impact ABS cabinet, simple power setting and lightweight design, the L-PWP06A can be flush-mounted on a ceiling, wall or even furniture. It is CE- and RoHS-compliant, and consistently delivers superb audio and music reproduction.

สอบถาม
HEX-8 8-Zone Expander

Expand your PAVA reach to 8 speaker zones with the HEX-8 Expander from Honeywell. It supports two audio channels simultaneously and provides independent audio control for each channel. Eight monitored contact inputs can be linked with a fire alarm system to trigger alert and evacuation messages in c

สอบถาม
2XD400 Variodyn D1 Class-D Power Amplifier

Compatible with the Variodyn D1 PAVA system, the 2XD400 power amplifier is controlled by its DOM4-8 or DOM4-24 Digital Output Module. Both LF inputs and control input are connected to the DOM via a cable. A mains cable is provided with the system.

สอบถาม
กล้องวงจรปิด (CCTV) Honeywell HBW2GR1V

กล้องไอพีกระบอก 1080P เลนส์ 2.7-13.5mm MFZ H.265. Network TDN Low-Light WDR 2MP/4MP IR Rugged Bullet กล้องวงจรปิด Honeywell สำหรับติดตั้งภายในและภายนอกอาคาร

สอบถาม
Projection Loudspeaker L-VBM20A/EN

This speaker offers max power of 30W and can be installed to meet virtually any outdoor requirement. It comes with a fire-resistant cable and is compliant with international IP65 standard, making it highly-resistant to dust, oil and other non-corrosive materials.

สอบถาม
ตู้ไฟอลาม Honeywell Morley UL 615-000-000 (STX)

ตู้ไฟอลาม Honeywell Morley UL โมเดล STX ตู้ไฟอลามสำหรับแจ้งเหตุเพลิงไหม้รองรับ Sensor สูงสุด 318 อุปกรณ์ หรือ โมดูลสูงสุด 78 โมดูล

สอบถาม
X-DA1500 High Efficiency Power Amplifier

X-DA1500 high efficiency power amplifier provides audio signal amplification for the X-618 Digital Public Address and Voice Alarm System. X-DA1500 is reliable, efficient and light in weight.

สอบถาม
Mixer Amplifier HN-MA90

Highly flexible mixer amplifiers are designed for a wide variety of voice and background music applications such as retail shops, restaurants and bars, service centers, houses of worship, warehouses etc.

สอบถาม